Boiler PK3e denitrification, Košice

Implementation site: heating plant Košice, boiler PK3e
Implementation term: 2011 – 2013

 Boiler, type Wet bottom boiler boiler conversion into gas fired boiler
 Boiler parameters
  • 210 t/h; 13.6 MPa; 540°C
  • Natural gas
 Scope of delivery
  • Technical design of boiler reconstruction
  • Documentation
  • Burning (new gas burners and safety lines)
  • Burner management system
  • Assembly supervision
  • Commissioning

 Guaranteed emissions

  • NOx < 100  mg/Nm3
  • COx < 100 mg/Nm3
 Milestones
  • Start: 5/2011
  • End: 3/2013
 
 Boiler, type Wet bottom boiler boiler conversion into gas fired boiler
 Boiler parameters
  • 210 t/h; 13.6 MPa; 540°C
  • Natural gas
 Scope of delivery
  • Technical design of boiler reconstruction
  • Documentation
  • Burning (new gas burners and safety lines)
  • Burner management system
  • Assembly supervision
  • Commissioning

 Guaranteed emissions

  • NOx < 100  mg/Nm3
  • COx < 100 mg/Nm3
 Milestones
  • Start: 5/2011
  • End: 3/2013