Flue gas recirculation piping K10, Štětí

Implementation site: paper mill MONDI Štětí, boiler K10
Implementation term: 2016

 Boiler, type Gas boiler with natural circulation
 Boiler parameters
  • 160 t/h; 9.4 MPa(a); 540°C
  • Natural gas
 Scope of delivery
  • Technical design of flue gas recirculation
  • Documentation
  • Flue gas recirculation piping and recirculation fan
  • Designer’s supervision of technology assembly
  • Participation in commissioning

 Guaranteed emissions

  • NOx < 100  mg/m3
  • COx < 40    mg/m3
 Milestones
  • Start: 4/2016
  • End: 10/2016
 Boiler, type Gas boiler with natural circulation
 Boiler parameters
  • 160 t/h; 9.4 MPa(a); 540°C
  • Natural gas
 Scope of delivery
  • Technical design of flue gas recirculation
  • Documentation
  • Flue gas recirculation piping and recirculation fan
  • Designer’s supervision of technology assembly
  • Participation in commissioning

 Guaranteed emissions

  • NOx < 100  mg/m3
  • COx < 40    mg/m3
 Milestones
  • Start: 4/2016
  • End: 10/2016