Boiler K2, K3, and K4 denitrification, Karviná

Implementation site: power plant Karviná, boilers K2, K3 and K4
Implementation term: 2015 – 2017

 Boiler, type Semi-tower, dry bottom boiler with the indirect feeding of pulverized coal
 Boiler parameters
  • 85 t/h; 7.45 MPa; 490°C
  • Black coal, natural gas
 Scope of delivery
  • Technical design of boiler reconstruction
  • Documentation
  • Combustion system (coal burners, pulverized fuel ducts,
    pulverized fuel feeders, OFA nozzles)
  • Disassembly and assembly of technology
  • Commissioning

 Guaranteed emissions

  • NOx < 390  mg/Nm3
  • COx < 80 mg/Nm3
 Milestones
  • Start: 4/2015
  • End: 9/2016
 
 Boiler, type Semi-tower, dry bottom boiler with the indirect feeding of pulverized coal
 Boiler parameters
  • 85 t/h; 7.45 MPa; 490°C
  • Black coal, natural gas
 Scope of delivery
  • Technical design of boiler reconstruction
  • Documentation
  • Combustion system (coal burners, pulverized fuel ducts,
    pulverized fuel feeders, OFA nozzles)
  • Disassembly and assembly of technology
  • Commissioning

 Guaranteed emissions

  • NOx < 390  mg/Nm3
  • COx < 80 mg/Nm3
 Milestones
  • Start: 4/2015
  • End: 9/2016