New boiler K7 285 t/h, Košice

Implementation site: Košice, boiler K7
Implementation term: 2013 – 2016

 Boiler, type Dry bottom boiler with natural circulation and three ring mills
 Boiler parameters
  • 285 t/h; 9.51 MPa; 540°C
  • Black coal, coke-oven gas, natural gas
 Scope of delivery
  • Technical design of new boiler
  • Documentation
  • Combustion system
  • Mill room
  • High-pressure heaters
  • Commissioning
 Guaranteed emissions
  • NOx < 120 mg/Nm3
  • COx < 100 mg/Nm3
 Milestones
  • Start: 9/2013
  • End: 9/2016
 Boiler, type Dry bottom boiler with natural circulation and three ring mills
 Boiler parameters
  • 285 t/h; 9.51 MPa; 540°C
  • Black coal, coke-oven gas, natural gas
 Scope of delivery
  • Technical design of new boiler
  • Documentation
  • Combustion system
  • Mill room
  • High-pressure heaters
  • Commissioning
 Guaranteed emissions
  • NOx < 120 mg/Nm3
  • COx < 100 mg/Nm3
 Milestones
  • Start: 9/2013
  • End: 9/2016