Optimization of boiler K1 - K6 operation, Mělník

Implementation site: power plant Mělník I, boilers K1 - K6
Implementation term: 2016 – 2018

 Boiler, type Dry bottom boiler with natural circulation and four hammer mills
 Boiler parameters
  • 230 t/h; 9.3 MPa(a); 535°C
  • Brown coal
 Scope of delivery
  • Technical design of boiler reconstruction
  • Documentation
  • Combustion system modification
  • Coal burners, modification of pulverized fuel ducts, and air ducts
  • Milling circuit modification
  • Disassembly and assembly of technology
  • Commissioning

 Guaranteed emissions

  • NOx < 230  mg/Nm3
  • COx < 100 mg/Nm3
 Milestones
  • K4:         5/2016 - 11/2016
  • K5-K6:   5/2017 - 12/2017
  • K1-K3:   4/2018 - 12/2018
 Boiler, type Dry bottom boiler with natural circulation and four hammer mills
 Boiler parameters
  • 230 t/h; 9.3 MPa(a); 535°C
  • Brown coal
 Scope of delivery
  • Technical design of boiler reconstruction
  • Documentation
  • Combustion system modification
  • Coal burners, modification of pulverized fuel ducts, and air ducts
  • Milling circuit modification
  • Disassembly and assembly of technology
  • Commissioning

 Guaranteed emissions

  • NOx < 230  mg/Nm3
  • COx < 100 mg/Nm3
 Milestones
  • K4:         5/2016 - 11/2016
  • K5-K6:   5/2017 - 12/2017
  • K1-K3:   4/2018 - 12/2018