Boiler K3 emission reduction, Kralupy nad Vltavou

Implementation site: chemical production premises Synthos Kralupy, boiler K3
Implementation term: 2016

 Boiler, type  Self-supporting, single-drum, over-pressure boiler with natural circulation
 Boiler parameters
  • 160 t/h; 9.6 MPa(a); 540°C
  • Natural gas, heating gas FCC, acetylene degas
 Scope of delivery
  • Technical design of combustion system modification
  • Documentation
  • Gas burners and flue gas recirculation piping
  • Disassembly and assembly of technology
  • Commissioning

 Guaranteed emissions

  • NOx <  100 mg/Nm3 
  • COx <  40 mg/Nm3
 Milestones
  • Start: 2/2016
  • End: 9/2016
 
 Boiler, type  Self-supporting, single-drum, over-pressure boiler with natural circulation
 Boiler parameters
  • 160 t/h; 9.6 MPa(a); 540°C
  • Natural gas, heating gas FCC, acetylene degas
 Scope of delivery
  • Technical design of combustion system modification
  • Documentation
  • Gas burners and flue gas recirculation piping
  • Disassembly and assembly of technology
  • Commissioning

 Guaranteed emissions

  • NOx <  100 mg/Nm3 
  • COx <  40 mg/Nm3
 Milestones
  • Start: 2/2016
  • End: 9/2016